Stack Gas Velocity Measurement Electronics from Canada
PCB assembly for thermal anemometer-based stack gas velocity sensors integrated with analyzers (9027.81). Calculates mass flow rates when paired with gas concentration data for EPA compliance reporting. Electrical part specific to emissions analysis instruments.
Duty Rate — Canada → United States
10%
Rate breakdown
9903.05.2910%Except for products described in headings 9903.05.85–9903.05.93, articles the product of Canada, as provided for in U.S. note 52 to this subchapter
Import Tips
• Document EPA Method 2 compliance for velocity traverse systems
• Probe heater control circuits require high-temperature component specs