Differential Pressure Flow Meter Orifice Plate from Japan

Stainless steel orifice plate with precise bore diameter for DP flow meters creating known pressure drop proportional to flow rate. Classified HTS 9026.90.40.00 as flow meter part per Chapter note 2(b) principal use. ASME/ISO 5167 compliant for custody transfer.

Duty Rate — Japan → United States

10%

Rate breakdown

9903.03.0110%Except for products described in headings 9903.03.02–9903.03.11, articles the product of any country, as provided for in subdivision (aa) of U.S. note 2 to this subchapter

Import Tips

Include beta ratio, Reynolds number range, and discharge coefficient; provide flange rating (ANSI 150-2500#); calibrate bore diameter to ±0.1% tolerance