Share:

Of apparatus based on the use of X-rays

Apparatus based on the use of X-rays or of alpha, beta, gamma or other ionizing radiations, whether or not for medical, surgical, dental or veterinary uses, including radiography or radiotherapy apparatus, X-ray tubes and other X-ray generators, high tension generators, control panels and desks, screens, examination or treatment tables, chairs and the like; parts and accessories thereof: > Other, including parts and accessories: > Other: > Parts and accessories: > Other: > Of apparatus based on the use of X-rays

Duty Rate (from China)

35%
MFN Base RateFree

Except for products described in headings 9903.03.02–9903.03.11, articles the product of any country, as provided for in subdivision (aa) of U.S. note 2 to this subchapter

Except as provided in headings 9903.88.05, 9903.88.06, 9903.88.07, 9903.88.08, 9903.88.10, 9903.88.11, 9903.88.14, 9903.88.19, 9903.88.50, 9903.88.52, 9903.88.58, 9903.88.60, 9903.88.62, 9903.88.66, 9903.88.67, 9903.88.68, or 9903.88.69, articles the product of China, as provided for in U.S. note 20(a) to this subchapter and as provided for in the subheadings enumerated in U.S. note 20(b) [to this subchapter]

Total Effective Rate35%

Products classified under HTS 9022.90.60.00

Varian High Tension Cable Set for TrueBeam

High-voltage cable assembly connecting generator to X-ray tube in Varian TrueBeam radiotherapy systems. HTS 9022.90.60.00 classification as wiring harness part for X-ray based apparatus. Rated for extreme voltages in radiation therapy delivery.

Fujifilm FDR Go Portable X-ray Bucky Assembly

Mobile detector bucky tray for Fujifilm FDR Go portable X-ray systems housing wireless flat panels. HTS 9022.90.60.00 accessory for mobile radiography apparatus. Carbon fiber construction for lightweight field deployment.

GE Discovery XR656 X-ray Table Top

Low-attenuation carbon fiber tabletop for GE Discovery XR656 X-ray examination systems with motorized longitudinal travel. Classified HTS 9022.90.60.00 as patient support accessory for X-ray apparatus. Bucky compatible surface.

Shimadzu RadSpeed X-ray High Tension Generator Module

Modular 80kW high tension generator for Shimadzu RadSpeed X-ray systems converting AC to pulsed DC for tube operation. HTS 9022.90.60.00 part of X-ray apparatus. Includes inverter and rectification circuitry.

Toshiba Aquilion X-ray Control Console

Touchscreen control desk interface for Toshiba Aquilion CT X-ray systems managing scan protocols and exposure parameters. HTS 9022.90.60.00 as dedicated X-ray apparatus accessory. Integrates generator controls and patient database.

Samsung X-ray Remote Control Pendant

Sterilizable wireless pendant controller for Samsung GF85 digital X-ray systems operating table movement and exposures. Classified HTS 9022.90.60.00 as dedicated X-ray apparatus accessory. IP68 rated for surgical environments.

Medtronic OEC C-arm Filter Wheel Assembly

Motorized copper/aluminum filter wheel for Medtronic OEC 9800 C-arm fluoroscopy systems shaping X-ray spectrum. Classified under HTS 9022.90.60.00 as X-ray apparatus accessory. Selects optimal kVp filtration for tissue penetration.

Hitachi X-ray Cooling Chiller Unit

Closed-loop dielectric coolant chiller for Hitachi X-ray tube heat management maintaining 20°C fluid temperature. Accessory under HTS 9022.90.60.00 specific to X-ray generators. Prevents thermal runaway during extended exposures.

Ziehm Vision RFD C-arm Dose Monitoring Sensor

Real-time air kerma and dose area product sensor array for Ziehm Vision RFD mobile C-arm systems. HTS 9022.90.60.00 accessory monitoring X-ray output. Integrates with control software for ALARA compliance.

GE X-ray Tube Housing Assembly

Replacement housing assembly for the X-ray tube in GE Optima XR220 systems, containing cooling and shielding components specific to X-ray generation. Classified under HTS 9022.90.60.00 as a dedicated part of X-ray radiography apparatus. Ensures safe operation and heat dissipation during medical imaging procedures.

Siemens Collimator for Artis Zee Angiography System

Adjustable lead collimator assembly for Siemens Artis Zee X-ray angiography systems, controlling the X-ray beam shape and size. Falls under HTS 9022.90.60.00 as an accessory integral to X-ray apparatus for interventional radiology. Reduces patient radiation exposure during procedures.

Philips Image Intensifier Assembly

Fluorescent screen and photocathode assembly amplifying X-ray images in Philips Veradius systems. Essential accessory for real-time fluoroscopy imaging classified under HTS 9022.90.60.00. Converts low-light X-ray patterns to visible display.

Canon X-ray Detector Panel CXDI-710

Flat panel digital detector for Canon CXDI-710 radiography systems capturing X-ray images directly. Classified as accessory part under HTS 9022.90.60.00 for X-ray apparatus. Provides high-resolution DR imaging replacing film cassettes.

Hologic Patient Positioning Laser Alignment System

Red laser alignment accessory for Hologic Selenia Dimensions mammography X-ray systems ensuring precise breast positioning. HTS 9022.90.60.00 as dedicated X-ray apparatus part. Projects positioning grid on patient for reproducible imaging.

Carestream Focus X-ray Grid Cassette

Anti-scatter grid cassette for Carestream Focus HD X-ray systems improving image contrast by absorbing off-angle radiation. Essential accessory classified under HTS 9022.90.60.00. Lead strips aligned parallel to primary beam direction.