Brainlab Novalis TX Beam Shaping Collimator Unit from China
Brainlab Novalis TX high-definition beam shaping collimator unit delivers conformal intensity-modulated radiation therapy (IMRT) beams. Features micro-multileaf design with 2.5mm leaf width for steep dose gradients. HTS 9022.90.1500 classification for radiation beam delivery units in stereotactic and IMRT ionizing radiation apparatus.
Duty Rate — China → United States
36.4%
Rate breakdown
9903.03.0110%Except for products described in headings 9903.03.02–9903.03.11, articles the product of any country, as provided for in subdivision (aa) of U.S. note 2 to this subchapter
9903.88.0125%Except as provided in headings 9903.88.05, 9903.88.06, 9903.88.07, 9903.88.08, 9903.88.10, 9903.88.11, 9903.88.14, 9903.88.19, 9903.88.50, 9903.88.52, 9903.88.58, 9903.88.60, 9903.88.62, 9903.88.66, 9903.88.67, 9903.88.68, or 9903.88.69, articles the product of China, as provided for in U.S. note 20(a) to this subchapter and as provided for in the subheadings enumerated in U.S. note 20(b) [to this subchapter]
Import Tips
• Submit beam commissioning QA data including PDD curves, profiles, and output factors
• Include leaf transmission and interleaf leakage test results per AAPM TG-142 standards
• Provide image-guided positioning system integration validation documentation