Endovenous Laser Ablation Grounding Pads

Large surface area conductive hydrogel pads for RF/laser vein ablation procedures treating varicose veins. Under HTS 9018.90.75.80 despite laser component due to electro-medical RF generator integration. Provides monopolar current return path during endovenous thermal ablation.

Import Duty Rates by Country of Origin

Origin CountryMFN RateCh.99 SurchargesTotal Effective Rate
🇨🇳ChinaFree+35.0%35%
🇲🇽MexicoFree+10.0%10%
🇨🇦CanadaFree+10.0%10%
🇩🇪GermanyFree+10.0%10%
🇯🇵JapanFree+10.0%10%

Alternative Classifications

This product could be classified differently depending on its characteristics or intended use.

9018.90.75Same rate: 35%

If RF vs laser endovenous ablation systems

Energy modality determines statistical category despite similar function.

3006.92.00.00Lower: 10% vs 35%

If classified primarily by conductive gel content

Pharmaceutical preparation when gel constitutes principal value.

3921.90.11.00Higher: 39.2% vs 35%

If foam pads lacking specified ablation current capacity

General medical-use plastics without electro-medical specification.

Not sure which classification is right?

Our AI classifier can analyze your specific product and recommend the correct HTS code with confidence.

Import Tips & Compliance

Thermal runaway prevention testing data and hydrogel conductivity specs required

Prove compatibility with specific vein ablation generators (VNUS, VN20)

Cosmetic procedure pads risk pharmaceutical classification under 3006

Related Products under HTS 9018.90.75.80

Patient Return Electrodes for Electrosurgery

Latex-free grounding pads providing electrical return path during surgical procedures using electrosurgical generators. Falls under HTS 9018.90.75.80 as essential safety accessories for electro-medical surgical apparatus. Prevents patient burns by dispersing high-frequency current safely.

Defibrillator External Pacing Leads

Sterile multifilament cables for transcutaneous cardiac pacing during emergency defibrillation procedures. Classified HTS 9018.90.75.80 as accessories for life-support electro-medical apparatus. Delivers precise millivolt pacing pulses through skin electrodes.

Biofeedback Sensor Interface Cables

Multi-signal cables connecting physiological sensors to biofeedback therapy monitors for stress management. HTS 9018.90.75.80 as electro-medical accessories aggregating EMG/GSR/HRV signals. Enables real-time patient training through visual/auditory feedback.

Nerve Conduction Study Ground Electrodes

Reusable stainless steel ground plates for EMG/NCS electrodiagnostic equipment measuring nerve/muscle electrical activity. Under HTS 9018.90.75.80 as precision accessories minimizing electrical noise during neuropathy testing. Provides stable reference potential for accurate waveform analysis.

Electromyography Needle Electrode Handles

Ergonomic insulated handles for concentric needle electrodes used in EMG muscle fiber analysis. HTS 9018.90.75.80 classification as electro-medical diagnostic accessories. Facilitates precise subcutaneous needle positioning while maintaining electrical isolation.

Cardiac Ablation Irrigation Pump Tubing Sets

Sterile fluid pathway sets connecting irrigation pumps to cardiac catheters during RF ablation procedures. Classified HTS 9018.90.75.80 as accessories for electro-medical cardiac rhythm management apparatus. Controls saline irrigation preventing thrombus formation and electrode overheating.