New

Ask Wove anything about tariffs.

Try Tariff Assistant

Steatite Ceramic Strain Insulator from Japan

Steatite-based ceramic insulator for dead-end strain applications in low-frequency distribution lines up to 69 kV, with high mechanical tensile strength. Its low-loss tangent suits transformer bushings too. HTS 8546.20.00.60 covers this as other high-voltage ceramic insulators.

Duty Rate — Japan → United States

12.5%

Rate breakdown

9903.05.4912.5%Except for products described in headings 9903.05.85–9903.05.92, articles the product of Japan, with an ad valorem (or ad valorem equivalent) rate of duty under column 1 less than 12.5 percent, as provided for in U.S. note 52 to this subchapter

Import Tips

• Ensure supplier provides tan delta test results under 0.006; label with ANSI C29.6 class for customs; watch for reclassification if used in medium-voltage only

Steatite Ceramic Strain Insulator from Japan — Import Duty Rate | HTS 8546.20.00.60