Motor starters and motor overload protectors

Electrical apparatus for switching or protecting electrical circuits, or for making connections to or in electrical circuits (for example, switches, fuses, lightning arresters, voltage limiters, surge suppressors, plugs and other connectors, junction boxes), for a voltage exceeding 1,000 V: > Other: > Motor starters and motor overload protectors

Duty Rate (from China)

37.7%
MFN Base Rate2.7%

Except for products described in headings 9903.03.02–9903.03.11, articles the product of any country, as provided for in subdivision (aa) of U.S. note 2 to this subchapter

Except as provided in headings 9903.88.05, 9903.88.06, 9903.88.07, 9903.88.08, 9903.88.10, 9903.88.11, 9903.88.14, 9903.88.19, 9903.88.50, 9903.88.52, 9903.88.58, 9903.88.60, 9903.88.62, 9903.88.66, 9903.88.67, 9903.88.68, or 9903.88.69, articles the product of China, as provided for in U.S. note 20(a) to this subchapter and as provided for in the subheadings enumerated in U.S. note 20(b) [to this subchapter]

Total Effective Rate37.7%

Products classified under HTS 8535.90.40.00

ABB TA35DU2.5 Motor Starter

High-voltage motor starter for industrial pumps exceeding 1,000V, featuring overload protection and manual reset capabilities. Classified under HTS 8535.90.40.00 for its primary function as a motor starter and protector in medium-voltage systems.

Schneider Electric TeSys GV2 ME Motor Overload Protector

Medium-voltage thermal overload relay for conveyor motors over 1,000V, with bimetallic strip actuation for precise protection. HTS 8535.90.40.00 applies due to its specific motor overload protection design for high-voltage circuits.

Rockwell Automation 1502 Motor Circuit Protector

Adjustable magnetic overload protector for 4,160V HVAC compressors, providing short-circuit and overload coordination. Classified in HTS 8535.90.40.00 for high-voltage motor-specific protection.

Square D 9065 Motor Starter

NEMA-rated across-the-line motor starter for 2,300V water pumps with integral overload protection. HTS 8535.90.40.00 covers this high-voltage combination starter-protector unit.

GE Multilin Motor Protection Relay

Digital motor overload protector for 13.8kV generators with microprocessor-based thermal modeling. Falls under HTS 8535.90.40.00 as advanced high-voltage motor protection exceeding 1,000V.

Cutler-Hammer CH Series Motor Overload Protector

Bimetallic overload relay for 6,900V steel mill motors with manual/automatic reset options. HTS 8535.90.40.00 classification for high-voltage industrial motor protection.

Lovato Electric RT1 Motor Starter

Compact high-voltage manual motor starter for 3,300V fans with built-in overload and short-circuit protection. Covered by HTS 8535.90.40.00 for voltages exceeding 1,000V.

MTE Controls High-Voltage Motor Protector

Solid-state motor overload relay for 11kV oilfield pumps with phase loss and unbalance protection. HTS 8535.90.40.00 applies to this specialized high-voltage protector.

Siemens 3RV2011-0JA10 Motor Overload Relay

This motor overload protector is designed for three-phase motors rated over 1,000V, protecting against thermal overload by monitoring current and tripping when limits are exceeded. It falls under HTS 8535.90.40.00 as a motor overload protector for high-voltage applications exceeding 1,000V.

Eaton Freedom Series Motor Starter

Full-voltage motor starter for 2,400V mining equipment, including overload relays and phase failure protection. Falls under HTS 8535.90.40.00 as specialized high-voltage motor starting and protection apparatus.