Shim Coil Assembly for Siemens Skyra MRI

Precision shim coils for Siemens Skyra 3T MRI fine-tune magnetic field homogeneity across the imaging volume. These electromagnetic coils are used solely for MRI field correction, qualifying under HTS 8505.90.70.00. Actively powered during operation to compensate for field imperfections.

Import Duty Rates by Country of Origin

Origin CountryMFN RateCh.99 SurchargesTotal Effective Rate
🇨🇳ChinaFree+35.0%35%
🇲🇽MexicoFree+10.0%10%
🇨🇦CanadaFree+10.0%10%
🇩🇪GermanyFree+10.0%10%
🇯🇵JapanFree+10.0%10%

Alternative Classifications

This product could be classified differently depending on its characteristics or intended use.

8505.90.40.00Same rate: 35%

If room temperature shim coils

Non-superconducting electromagnets for field correction use different temperature provisions.

9030.89.01.00Same rate: 35%

If when including field monitoring sensors

Electromagnets with integrated measuring functions classify as instruments.

8505.20.00Higher: 38.1% vs 35%

If industrial electromagnetic brakes

Similar coil technology for mechanical holding devices uses different functional headings.

Not sure which classification is right?

Our AI classifier can analyze your specific product and recommend the correct HTS code with confidence.

Import Tips & Compliance

Field mapping test data required for customs validation; ensure cryogenic compatibility certification; avoid 8529 classification for signal processing coils

Related Products under HTS 8505.90.70.00

Siemens MAGNETOM Superconducting Electromagnet

This superconducting electromagnet is designed specifically for use in Siemens MAGNETOM MRI scanners, generating the strong, stable magnetic field required for high-resolution medical imaging. It falls under HTS 8505.90.70.00 as it is used solely or principally for MRI apparatus (excluding heading 9018 medical instruments). The coil assembly uses niobium-titanium wire cooled by liquid helium to achieve fields up to 3 Tesla.

GE Signa HDxt MRI Cryostat Electromagnet

The GE Signa HDxt electromagnet features a cryostat housing for superconducting operation in 1.5T MRI systems, providing homogeneous magnetic fields essential for clinical diagnostics. Classified under HTS 8505.90.70.00 due to its principal use in MRI apparatus separate from complete 9018 systems. Includes quench protection systems for safe helium boil-off management.

Philips Ingenia 3.0T MRI Main Magnet Assembly

Philips Ingenia 3.0T main magnet uses zero-boil-off superconducting technology for continuous high-field MRI operation in hospitals. This electromagnet is dedicated to MRI field generation, qualifying for HTS 8505.90.70.00 as a principal component excluding assembled 9018 apparatus. Features advanced shim coils for field homogeneity optimization.

Toshiba Vantage Titan MRI Gradient Magnet

While primarily gradient coils, the Toshiba Vantage Titan's electromagnetic assembly generates precise field gradients for MRI spatial encoding. Specifically designed for this 1.5T MRI model, it qualifies under HTS 8505.90.70.00 for MRI-principal electromagnets. Features water-cooled copper windings for high-speed imaging sequences.

Hitachi Echelon Smart 1.5T Electromagnet

Hitachi Echelon Smart MRI electromagnet provides stable 1.5T field with Pianissimo noise reduction technology for patient comfort. This superconducting coil assembly is used principally in MRI scanners, falling under HTS 8505.90.70.00 excluding complete 9018 systems. Includes integrated shim system for field uniformity.

Cryogenic Electromagnet Leads for Philips Achieva

High-current persistent current leads for Philips Achieva 3T MRI superconducting magnets minimize heat leak into cryostat. These specialized electromagnetic conductors are principal components of MRI magnets under HTS 8505.90.70.00. Use vapor-cooled design with OFHC copper for optimal thermal performance.