Chamber Insulation Panel for Surgical Autoclaves
High-density ceramic fiber insulation panels lining chambers of surgical autoclaves to maintain sterilization temperatures efficiently. Rated for 150°C continuous exposure. Part under HTS 8419.90.50.40.
Import Duty Rates by Country of Origin
Alternative Classifications
This product could be classified differently depending on its characteristics or intended use.
If general mineral wool insulation products
Slag wool or rock wool if not specific to sterilizer machinery.
Not sure which classification is right?
Our AI classifier can analyze your specific product and recommend the correct HTS code with confidence.
Import Tips & Compliance
• Declare fiber composition for OSHA/EPA compliance
• Thermal conductivity test data required
• Not building insulation (68.09)
Related Products under HTS 8419.90.50.40
Vacuum Pump Assembly for Medical Sterilizers
This vacuum pump module creates the necessary vacuum for pre-sterilization air removal in medical steam sterilizers, ensuring thorough steam penetration for sterilizing bandages, linens, and equipment. Built with corrosion-resistant materials for repeated high-temperature cycles. Classified in HTS 8419.90.50.40 for parts of medical sterilizers.
HEPA Filter Housing for Laboratory Sterilizers
Housing unit for HEPA filters in laboratory autoclaves, maintaining sterile air during cooling and aeration phases post-sterilization of biohazard materials. Constructed for high-temperature tolerance. Classified under HTS 8419.90.50.40 as laboratory sterilizer part.
Temperature Sensor Probe for Lab Autoclaves
PT100 RTD probe for monitoring chamber temperature in laboratory autoclaves during sterilization of Petri dishes and reagents. Steam-rated sheath for direct immersion. Part of laboratory sterilizers per HTS 8419.90.50.40.
Drain Valve Assembly for Medical Sterilizers
Automated drain valve for removing condensate from medical sterilizers post-cycle, preventing bacterial growth in surgical tool sterilization. Includes thermal actuator. HTS 8419.90.50.40 classification.
Cycle Printer Interface Module for Lab Sterilizers
Interface board connecting laboratory sterilizers to thermal printers for documenting sterilization cycles per GLP standards. USB/RS232 ports. HTS 8419.90.50.40 for lab sterilizer parts.
Safety Interlock Switch for Medical Autoclaves
Magnetic reed switch preventing door opening during pressurized sterilization in medical autoclaves. Fail-safe design for patient safety. Classified HTS 8419.90.50.40.